ORC waste heat recovery - INDUCAL®
INDUCAL-„industrial caloric" describes our organic rankine cycle-waste heat recovery product line that makes it possible to recover waste heat efficiently from industrial plants, such as glass and steel mills or big engines for the generation of electricity.
The primarily named waste heat sources nowadays are mainly not recovered since most of the time they are only available on low temperature levels (up to 300°C/572°F) with small power outputs. Based on these reasons such waste heat potentials can not be converted into electricity with the water steam cycle, because of the high investment costs of such plants and physical properties of water.

1. Motor power plant

2. Exhaust heat exchanger

3. Primary cycle
4. Thermal oil pump

5. Pre-heater-evaporator unit

6. Fresh steam pipe

7. Turbine

8. Generator

9. Recuperator-condenser unit
10. Condensate feed pump

11. Cooling system